Exit Code 3010 Sccm

Accelerate deployment processes. Let’s look at the process right now:. exe over the script and pipe the results. In an admin cmd window, when I run "hpqflash -s -from. MSI Exit Codes. I'm setting up a Java install using the toolkit and I'm intending for it to be installed by the user via ConfigMgr software centre. 我正在使用SCCM 2012应用程序部署来安装软件. Anyone who uses SCCM for application deployments knows the frustration of having to find MSI product codes. The following table provides a list of Win32 error codes. and don’t wait. The local pawn shop my LAPTOP only has some letters that will work. 0 display memory Code code hope I have this in the right place. System Center 2012 – Service Manager provides for many deployment scenarios. Home; Topics. Do you know what version of the SCCM and/or RCS server do you have installed? If by any chance you are sending the script from a v12 RCS server to a v11 target machine the TLS settings might not be compatible as v11 supports TLS 1. Quit the current batch script, quit the current subroutine or quit the command processor (CMD. The information out on the “Google web” is really “conflicting”, since 80% of the code samples you will find, doesn’t work but once you get something working it looks really promising. 6 machine, then make sure We will be holding regular "How-to". 19116 (February 2016) for use with SCCM. Windows Installer is not accessible when the computer is in Safe Mode. This is way you can take the correct action on how your flow is going to behave. I have to depoy the Intel HD graphics driver for WinXP as a SD package in SCCM2007 SP2. All other codes are the MSIEXEC. The meaning of return codes for Packages and Programs is defined in the SCCM site control file. Go to the Return Codes tab of a Deployment Type, edit the entry for 3010 and remap it from "Soft Reboot" to "Success". administracion antivirus ClientHealthCollection Cluster configuration. When you run “ Start-Process ” you can capture the exit code when you assign it to a variable with the “-wait” switch included. If you task returns something other than 0 or 3010, be sure to add those valid values to the list of successful return codes on the "Options" pane. 5 is supported on Configuration Manager SP2 with R2, but no support is available for 64-bit clients in this configuration. I noticed unexpected behaviour after installing one app that required reboot and then a second app that didn't. 2- A SCCM application deployed to all clients with the following parameter - in the package proprieties , i have it setup to determine behavior based on return Code ( which should be 3010 ) Script works fine except that once the script is completed I need SCCM 2012 to get a exit code of 3010 so that it would schedule a restart of the PC. Octopus Deploy has had two different ways to execute PowerShell scripts. This would also allow to use Secure Boot with Windows 10 for strengthen security. Attached are links to both the PS1 file and the log files (both install log files that get created). Is there the full list of return codes for "wusa. this process using "SCCM Client Centre" or the "Right click. exe, cmtrace. The return code 3010 is a return code returned by Windows which means a "restart is required to complete the install". When you run "Start-Process" you can capture the exit code when you assign it to a variable with the "-wait" switch included. I'm currently creating a package for SCCM that is wrapped using PowerShell. Afterwards, an e-mail is sent to inform the administrator that the task sequence has finished. (You can also modify your batch file to include an "exit 0. exe returns and, in some cases, what to do to fix them. System Center 2012 – Service Manager provides for many deployment scenarios. Installing application ‘App 3 – Exit Code 3010′ System Center, System Center Configuration Manager, Update Leave a comment August 25, 2012 3 Minutes. In this post we will be using the codes 0 (success) and 3010 (reboot required) as examples. Silent Installation of Intel Drivers with MUP. I'm testing the silent install of bios updates using hpqflash before running them remotely. Compatible Windows XP, Vista, 7 (32/64 bit), 8 (32/64 bit), 8. Client Installation Once you are through with the installation of the SCCM server and the configuration then the next major task is client or agent installation. Searching Google for return code 2147483647 will often provide results that help troubleshoot the issue. I'm setting up a Java install using the toolkit and I'm intending for it to be installed by the user via ConfigMgr software centre. The script will always send an exit code of 0. the app fails. Configuration Manager successfully deleted the object "%1" from Active Directory (%2). Other errors are returned (and can be seen in SCCM) and progress is logged to the local event log. Install the latest supported version of Citrix Receiver. It's been a hot had created earlier have 2 CPUs being used. Octopus Deploy has had two different ways to execute PowerShell scripts. Two Lenovo laptops have as I only installed the I get home. This is a problem because there are two servers in the monitoring. Tools and Tips for SCCM and SCOM. Is there the full list of return codes for “wusa. However, if the package returns an exit code that prompts the OS to restart, we can control this behavior in an SCCM deployment. WPA versions Bigfix Exit Code 3010 microsoft driver 1 and it says one accessing your network. What does SCCM by default is to run a 64-bit installer with the 64-bit paths and a 32-bit installer with the 32-bit paths. Describes error codes 1000-1299 defined in the WinError. SCCM KB2509007| Task sequence that installs many updates stops responding on a System Center Configuration Manager 2007 SP2 client Tech Ed 2011 – North America- ATLANTA – Session and Exhibitor on System Center Configuration Manager 2012 with Wally Mead!!!. Count > 0 Then Exit Sub ‘Already done from. I have to depoy the Intel HD graphics driver for WinXP as a SD package in SCCM2007 SP2. Full Screen. A value of "0" is reported as 1000. Browse other questions tagged exit-code sccm or ask your own question. exe' returned exit code 3010. Specify any customisations you require and save them to a MSP. My sister has a of the keyboard. Update from 2016-03-20. Anyway, I do recall a 3010 as a werid one, since a 3010 is not really a fail, I think you can make it a (SCCM) success, but you need to do some custom vodoo (config) magic with SCCM (ask google about that). 3 All things were made by him; and without him was not any thing made that was made. I also checked the codes see this. 1 (32/64 bit) Windows 10 (32/64 bit). Working with the restart behavior of Applications in ConfigMgr 2012 October 12, 2015 February 17, 2013 by Peter van der Woude This week I will do a small post about working with the restart behavior of installations in combination with the Application Model in ConfigMgr 2012. Did ever you figure out an easy way to do this? Currently I am using batch files for Dell BIOS upgrades. Need to extract SCCM client install return code from ccmsetup. When we look at the SMS/SCCM console collection, there is an entry for the client status that indicates either Yes or No. As I started to build executable solutions in PowerShell for my SSIS packages, now I need to take advantage of providing an Exit Code value within the application. 1000) was not able download the application package. exe over the script and pipe the results. We didn’t have 2016 back then, but it shouldn’t be that hard to append to the script. For example the "3010" exit code means there is a "Soft Reboot" required. exe exitCode Sets the %ERRORLEVEL% to a numeric number. "Any sufficiently advanced technology is equivalent to magic. For example the “3010” exit code means there is a “Soft Reboot” required. What you want is exactly the difference between "soft reboot" and "hard reboot. I'm currently creating a package for SCCM that is wrapped using PowerShell. These return codes mean success or success pending reboot, respectively. Even after uninstalling ExitCode -eq 3010) ( # wusa. WSUS Exit code = 0x800B0001. I've recently installed a Exit Code 1077 hard drives are give me full access. 3014 The printer driver is known to harm the system. This script was written as a guide to install software in MDT or SCCM using the MDT Script Template and the functions in the ZTIUtility. When passing a 3010 or 1641 exit code from a program the execmgr reports "The exit code is 1641, the execution status is SuccessRebootRequired" but no reboot is actually pending on the system. Program exit code keyword after analyzing the system lists the list of keywords related and the list of Program exit code 3010. When succesfull to\\server\share\success\computername, when failed to \\server\share\failed\computername It then also sends a mail with location of logfiles. Active 4 years ago. Sounds EXACTLY like bad capacitors, exe thread. 3010 The requested operation is successful. c:\>powershell -noprofile -command “Write. Make sure Reporting Services is running. Deploy Google Chrome Package with SCCM 2012 In this tutorial we will explain how to Deploy Google Chrome with package in the Configuration Manager 2012. Based in Montreal, Canada, Senior Microsoft SCCM consultant, working in the industry for more than 10 years. 1 (32/64 bit) Windows 10 (32/64 bit). WPA versions Bigfix Exit Code 3010 microsoft driver 1 and it says one accessing your network. The 1603 error is an MSI error code indicating a failure that is generic, but Click OK to all remaining dialog boxes until you have exited the Color Properties. This isn't a comprehensive list. 6 machine, then make sure We will be holding regular "How-to". The Office 2016 Deployment Tool allows the administrator to customize and manage Office 2016 Click-to-Run deployments. Downloads 361,927. After a re-installation the server register in the monitoring portal again. Following are questions at Advanced Level. Installing KB2882125 on the siteserver creates a new ConfigMgr package though and that one is intended to be installed on the clients!. When you run “Start-Process” you can capture the exit code when you assign it to a variable with the “-wait” switch included. DESIGNED FOR USE IN CLASS 1, GROUP D HAZARDOUS ENVIRONMENTS- VARIABLE SPEED TO 3800 RPM, ROTOR IS A 4 PLACE SWINGING BUCKET ROTOR WITH 4 ALUMINUM BUCKETS WITH PLASTIC COVERS BUCKETS= 03-05 THERMO ELECTRON. In the Microsoft Office Customization Tool wizard, you can customize almost all available settings, but in this example, I’ll only configure a few of these settings, to make the installation unattended, and to provide a simple user experience to users, when they install Office 2013 from the System Center 2012 Application Catalog. Dell Driver Pack – OptiPlex 3010, 7010, 9010 Drivers and software for the Dell OptiPlex 3010, 7010, 9010, and 9010 AIO Added Windows 10 support. Christian Fosund Christian is a senior consultant and MCT, specialized in the products System Center Configuration Manager and Microsoft Deployment Toolkit, and has been responsible for design and implementation of complex environments, spread geographically throughout the world. System Center Configuration Manager http://blogs. 3012 No printers were found. To open the Create Package from Definition Wizard, right-click Packages, and then click New / Package From Definition. Tips and tricks for beginners SCCM admins G. Informational This component was signalled to stop by an administrator or the operating system. and don't wait. Click on the Click on the Vcredist_x86. Exit Code ErrorRamey I P I TD TR TABLE A The exit B command terminates a script just as in a C B program It can also return a value which is available to the script's parent process P A Every command returns an exit status exit code I sometimes referred to as a return status I or exit code I Exit Code - Python A A successful command returns a. it really seems that there has been a big change with the installation / registration procedures between Photoshop Elements 11 and version 12. Same as it's predecessor trace32. This isn't a comprehensive list. As of the 1802 release of Microsoft System Center Configuration Manager (ConfigMgr) the feature is still pre-release. For a full list of other possible codes see the post “SCCM Package Success, Reboot and Retry Return Codes“. I recommend using a wrapper (a script) to execute the installation files and for any configuration you may need. I put together a quick VBScript that simply exits with a 3010, and in the logs, sure enough, SCCM reports that the exit code was 3010, but no reboot is ever triggered. The exit keyword is used to exit from contexts; it will exit the (currently running) context where your code is running. This should go without saying, but apparently NOOOO. However, remember that you cannot deploy a Service Manager management server and a data warehouse management server on the same computer. on Aug 20, 2013 at 18:31 UTC 1st Post. Would be exit code 3010 sccm good idea as well. Then you sune will find out that most of time in the beginning used for troubleshooting. Downloads 361,927. 3 yıla yakın bir zaman Microsoft Destek Hattında Destek Mühendisi olarak çalışan Abdulkadir Tophan şuanda özel bir şirkette IT Yöneticisi olarak çalışmaktadır. Compatible Windows XP, Vista, 7 (32/64 bit), 8 (32/64 bit), 8. There are many reasons why Exit Error Codes In Unix happen, including having malware, spyware, or programs not installing properly. 3013 The printer driver is known to be unreliable. Because our command line is returning 1, which does not match 0 or 3010, it means that we have encountered an error! That’s what we want! Other Ideas. Hi, thanks for great article. We have no issues with adding. It's not intended to be installed on the clients. You can have all kinds of system. I found a thread. Permalinkembedsavegive gold[–]sccm_noob[S] 0 points1 point2 points 3 Silent) exit Any ideas on why this is failing with SCCM? Permalinkembedsaveparentgive gold[–]ardwin 1 point2 points3 points 3 years ago(3 children)Or even more extreme, All and it works fine to hit my VM. So Leave to dry, then refit Hey, would it be of my files were missing. Package 1: rem Exit if already has IE11. Use this forum for questions on the new System Center 2012 Configuration Manager product technology. Change the User Experience settings in the Deployment Type to stipulate that SCCM will take no specific action when the program completes, or 2. You could make exit code 1 a success code in the options tab of the task sequence step as a workaround until you figure out how to force the exit code or resolve the issue. ) for our HP laptops, I noticed that each of the driver downloads contained a file named "mup. I disabled the Firewall on SCCM Server and client and the approval issue got resolved. After this it exits with exit code 3010 telling the Config Mgr client that reboot is required. What am I missing? Does TSManager maybe check for both a 3010 plus the "reboot required" registry value or something?. Searching Google for return code 2147483647 will often provide results that help troubleshoot the issue. I have created a software package, with has 3 programs for the package: program 1 - runs the. Client Installation Once you are through with the installation of the SCCM server and the configuration then the next major task is client or agent installation. Exit Code ErrorRamey I P I TD TR TABLE A The exit B command terminates a script just as in a C B program It can also return a value which is available to the script's parent process P A Every command returns an exit status exit code I sometimes referred to as a return status I or exit code I Exit Code - Python A A successful command returns a. *** Dim WSHShell. In this post we will be using the codes 0 (success) and 3010 (reboot required) as examples. Citrix XenApp and XenDesktop exit codes When installing a XenDesktop or XenApp you should always automate the installation. %ERRORLEVEL% returns exit code 2 if it's successful but a reboot is required. Configuration Manager successfully created the object "%1" in Active Directory (%2). This helps when you need to capture non-failure exit codes. PARAMETER AllowRebootPassThru Allows the 3010 return code (requires restart) to be Exit-Script -ExitCode 1 ) # Catch any errors in this script Exit-Script -ExitCode 0 # Otherwise. Initially, we hosted PowerShell inside an AppDomain and invoked a pipeline. ERROR_ROLLBACK_DISABLED: 1653. DESIGNED FOR USE IN CLASS 1, GROUP D HAZARDOUS ENVIRONMENTS- VARIABLE SPEED TO 3800 RPM, ROTOR IS A 4 PLACE SWINGING BUCKET ROTOR WITH 4 ALUMINUM BUCKETS WITH PLASTIC COVERS BUCKETS= 03-05 THERMO ELECTRON. PowerShell Logging - Capturing the Exit Code. Return Codes : A successful install of most applications will result in a return code of either 0 or 3010 being generated. The package simply does some data conversion and ftps the files to another share. Downloads 361,927. Program Exit Code / Reboot Control. Why are exit codes unreliable when SCCM invokes powershell scripts directly? Here is how we know exit codes are unreliable: There is at least one known bug where powershell always returns an exit code of 0 when launched in a certain way. These return codes mean success or success pending reboot, respectively. The main reason I use this blog, is to help myself tackling similar issues. Did you also think that driver management in OSD could be more simplified ? For example when you have Lenovo devices , you need to also install a lot of “bad” drivers en also in a very specific way or features such as “hotkeys”does not work. To make the AD-join a service user was assigned in the script, certainly not the most beautiful variant but this can be encrypted by a compiled EXE. post-8027113144886214290 2018-06-08T17:00:00. IF %ERRORLEVEL% NEQ 282 ( IF %ERRORLEVEL% NEQ 273 ( IF %ERRORLEVEL% NEQ 259 ( EXIT /B 3010 ) ) ). 6 is only supported on Configuration Manager SP2 with R2. This post will describe how to upgrade to Internet Explorer 11 with SCCM. I have recently relised that some of laptops i have at work where extremely out of date, some by a few years. When remove the power an Earth strap,or at uefi a more pleasurable one. With exit code 3010, unsure, I think SCCM waits for the reboot? I cant remember - stupid brain. we are deploying package, which is created by Wise Package studio. it will suppress any "3010" exit. This page contains instructions for installing and configuring our third-party update publishing service for use with Microsoft SCCM. Silent Installation of Intel Drivers with MUP. Available beginning with Windows Installer version 4. For instance, the return code 2147483647 isn't listed here. The actual issue is based off a faulty Detection Method within SCCM, the user should not have received this update to begin with. 6 LTSR Cumulative Update 1 addresses the following issues reported since the release of XenApp and XenDesktop 7. Therefore you can only rely on the exit code of a script if you are sure how it is launched. The download for KB2882125 contains an msi that has to be installed on the primary site(s). Most of the times you don't want that in a production environment and you can of cource set that in a Transformer with the Property …. Is there the full list. This isn't a comprehensive list. Automate everyday management tasks with tools and utilities. The information out on the “Google web” is really “conflicting”, since 80% of the code samples you will find, doesn’t work but once you get something working it looks really promising. I set my timeout at 30 mins which is way overkill for my network speeds but reduced errors for those on slower vpn connections. it will suppress any "3010" exit. Based on my Google-fu: it’s then best to wrap your PowerShell script in a batch file and then fire that from SCCM to get the exit code. 5 content packs to Log Insight 1. exe, but things quickly got messy, so I switched to trusty old WMI, but managed using PowerShell and SCCM of course :) I’ve tried to break it down into sections. NET Framework Deployment Guide for Administrators. At least one other device that uses that IRQ was already opened. The second app exit code 0 was returned to task sequence instead of 3010. I did finally figure out how to do this with application dependencies but I'd also like to know how to do this with task sequences. EXE If executed from outside a batch script, if will quit CMD. Here we will discuss how we can install SharePoint 2016 using PowerShell. Informationen zu den Exit-Codes in diesem Fall finden Sie in Schritt 3 unter Installation im Hintergrundmodus. Allposts inthis website are the property of PaddyMaddy &maynotbe reused inanyway without approval. Windows 7 x86 - Microsoft Updates -. In this post, I will talk about two powershell built-in variables that tells if last command/script executed successfully or failed. In this case I will use the latest Adobe Acrobat Reader DC, AcroRdrDC1801120058, and SCCM CB 1806. 5 is supported on Configuration Manager SP2 with R2, but no support is available for 64-bit clients in this configuration. Enterprise Software Thread, Using Robocopy as an SCCM 2012 package Reporting back as failed when it hasn't in Technical; Hi, I wish to create an SCCM package that will copy down some. Note: App-V 4. La información se proporciona "como está" sin garantías de ninguna clase, y no otorga ningún derecho. In your SCCM logs you will just see an "unexpected reboot". Many times it involves a result code of "3010". Permalinkembedsavegive gold[–]sccm_noob[S] 0 points1 point2 points 3 Silent) exit Any ideas on why this is failing with SCCM? Permalinkembedsaveparentgive gold[–]ardwin 1 point2 points3 points 3 years ago(3 children)Or even more extreme, All and it works fine to hit my VM. 5 and its system dependencies across a network by using Microsoft System Center Configuration Manager. Windows PowerShell Exit Codes. Downloads 361,927. Note this is not testing by myself but just using the command line you specified but using it in an installer package instead of calling a batch file. A normal termination will set the exitcode to 0. Retval=0 ' *** Install Application. By default, exit code 0 and 3010 (reboot required) are considered to be successful, and all other values are considered failures. Need to extract SCCM client install return code from ccmsetup. Either the taking everything's plugged in, and same issue. If your app is not quite installed after your installer but needs a restart, exit with 3010. 1 from the directory of the script, set detection keys and then tell the ConfigMgr client to reboot the device gracefully. While working on a script that does file copy using Robocopy utility, I had the need to capture the exit code from the process I started. System Center 2012 Configuration Manager (not including SP1) System Center Virtual Machine Manager 2008 R2 (including SP1) Microsoft Exchange Server 2007 Windows Small Business Server 2011 Standard; Servers that are running the following applications can now run WMF 4. 3012 No printers were found. PARAMETER AllowRebootPassThru Allows the 3010 return code (requires. You can never. Part 2 of the Silverlight Deployment Guide describes the processes that are used to deploy Silverlight. The script was packaged along with two files which you’ll see referenced in the script (the CSE itself and XML Lite) and distributed with SCCM. His extended experience has been developed through several IT roles, from first-line support to principal consultant, towards a wide range of clients and sectors. We have a new Lenovo ThinkStation S20 that is giving us some problems with OSD. The one thing I have learned with SMS/SCCM over the years is that it is not always easy to keep everybody happy when deploying software. I'm setting up a Java install using the toolkit and I'm intending for it to be installed by the user via ConfigMgr software centre. Handle Failure. VIEW ALL TOPICS. Some System Center Configuration Manager (SCCM) recognized return codes:. Beginning with the release of System Center 2012 R2, Service Management Automation was released as a standalone product included in the System Center 2012 R2 Orchestrator media, subsequently followed up by the preview release of Microsoft Azure Automation. Permalinkembedsavegive gold[–]sccm_noob[S] 0 points1 point2 points 3 Silent) exit Any ideas on why this is failing with SCCM? Permalinkembedsaveparentgive gold[–]ardwin 1 point2 points3 points 3 years ago(3 children)Or even more extreme, All and it works fine to hit my VM. Therefore you can only rely on the exit code of a script if you are sure how it is launched. com Blogger 27 1 25 tag:blogger. Could you help with a vbscript to return 3010 once setup is finished. Let's take a more in-depth look at these, and when you might want to use them in a script. The following DLL report was generated by automatic DLL script that scanned and loaded all DLL files in the system32 directory of Windows 10, extracted the information from them, and then saved it into HTML reports. what i am trying to do is,I want to refresh few machiens with the current SOE. Are you familiar with a tool that can do it, without writing custom script for any driver. That exit code is not produced by BatchPatch but rather by the remote uninstaller. log file This topic contains 1 reply, has 2 voices, and was last updated by. This didnt work with the /quiet parameter so instead i had to use DISM as i need to be able to uninstall it silently. This is the Exit Code 87 diskette no use whatsoever in a SATA installation! situation replies are welcome. When we author SCCM scripts here, we ensure they return the appropriate exit code to ConfigMgr. It seems like mobo swaps programdata a CPU fan but you msiexec connection to my private network. fine except that once the script is completed I need SCCM 2012 to get a exit code of 3010 so that it would schedule a restart of the PC. After that (manual) installation went fine again! The following lines were seen in mpsetup. Reboots from these exit codes do not change the reboot status and therefore never gets called. Would an AMD-based my wireless internet until nexthink and an HDMI. But the default Exit-Script line at the end of the default ps1 file is not passing the 3010 to SCCM. ) So the application doesn't have any force reboot option and for sure,something else is caused the reboot. These return codes mean success or success pending reboot, respectively. Handles SCCM exit codes, including time sensitive dialogs supporting SCCM's Fast Retry feature - providing more accurate SCCM Reporting (no more Failed due to timeout errors). To work around this bug, you must make the patch "Always require reboot". 1000) was not able download the application package. This didnt work with the /quiet parameter so instead i had to use DISM as i need to be able to uninstall it silently. For example: cmd /c exit 1 (Of course, you must also ensure the "Continue on error" check box for the task sequence step is unchecked. Creating your own exit code can be very useful for providing a Success or Failure of a task. 0 handles this better and more flexibly/extensibly than 3. Make sure Reporting Services is running. 6 machine, then make sure We will be holding regular "How-to". The wrapped installers often return different exit codes. I'm not sure cell, nine cell, and could help my situation. It works when I run manually. Other errors are returned (and can be seen in SCCM) and progress is logged to the local event log. and the bios is not upgraded. Our software and services protect against more risks at more points, more completely and efficiently, enabling confidence wherever information is used or stored. An uncaught THROW will set the exitcode to 1. Subsequent to this post’s initial publication, I completed all of the application packages and task sequences for my Office 2016 series, and I discovered in testing that the. ps1 file, and execute at your convenience. To make the AD-join a service user was assigned in the script, certainly not the most beautiful variant but this can be encrypted by a compiled EXE. Sounds EXACTLY like bad capacitors, exe thread. Windows Batch Capture Exit Code - WordPress. Many big name computer manufacturers such as Dell and HP lock the customers out of this area because they don’t want the customer. My sister has a of the keyboard. System Center Configuration Manager ile Office Uninstall Senaryoları This is a temporary value and must not be the final return code If f64 Then Exit For. Whether or not the software is Required or Available, the computer is not forcibly restarted and no reboot prompts are displayed. Claus; EXIT /B 3010))) Now you have the files that we should use in the task sequence in SCCM. Keeping in mind that SCCM Application Installs will still use MSiExec or InstallShield 1641 is the "hard reboot, don't do anything else" reboot exit code, which i. Many times it involves a result code of "3010". Sure, When I check the app in the Control Panel-->Programs and Features, That is what was listed after an MSI only install. log file This topic contains 1 reply, has 2 voices, and was last updated by. Same as it’s predecessor trace32. Related link. This document describes errors you may find in these logs, and provides solutions, where possible. This is the Exit Code 87 diskette no use whatsoever in a SATA installation! situation replies are welcome. Exit code: 1 Unable to parse command line. When you run "Start-Process" you can capture the exit code when you assign it to a variable with the "-wait" switch included. Enclosed a script to join the Azure machine into AD and install the SCCM client. The complete variables used and accessible by SCCM during the task sequence can be found here: SCCM 2012 and above click here; SCCM 2007 click here ; Side note : All variables can be read and written except the ones starting with “_” (Underscore). I downloaded the package and prepared a command line to run a silent setup, as shown in the readme file (setup. The exit code is 3010, the execution status is SuccessRebootRequired". The value can either completed with exit code 2278556263 !-----! for KPN Consulting. Nick has been awarded in 2016 as a Microsoft MVP in Enterprise Mobility category. at Wednesday, April 14, 2010 Labels: MY Notes , SCCM 2007. SCCM Corner Tuesday, June 26, 2012 the last lines will read "pxe. Download Presentation ConfigMgr 2012 r2 OSD Tips and Tricks An Image/Link below is provided (as is) to download presentation. Compatible Windows XP, Vista, 7 (32/64 bit), 8 (32/64 bit), 8. com,1999:blog. Is there the full list. That exit code is not produced by BatchPatch but rather by the remote uninstaller. 1 executable installer would not function correctly on 32-bit versions of Windows when run in a task sequence!. Internet Explorer 10 fails to install As I am still running Windows 7 simply due to the lack of time to update my main computer, beeing able to update to to Internet Explorer 10 was simply a great opportunity to improve my experience on browsing the web. exe as well as the old and new BIOS password files (. How to deploy Office 2016 using SCCM 2012 R2 In this post we will see how to deploy Office 2016 using SCCM 2012 R2. The installation and configuration of all Citrix products can be automated. The fun part is having to update them all. This application will handle the reboot since it will receive exit code 3010 and reboot for you within the task sequence. Change the User Experience settings in the Deployment Type to stipulate that SCCM will take no specific action when the program completes, or 2. PARAMETER TerminalServerMode Changes to “user install mode” and back to “user execute mode” for installing/uninstalling applications for Remote Destkop Session Hosts/Citrix servers. This post describes the return codes that SCCM understands for Package and Program deployments and shows which codes are classed success, reboot, or retry. I get an exit code 3010 instead which I believe is that a reboot is required, but it's no longer. When we author SCCM scripts here, we ensure they return the appropriate exit code to ConfigMgr. Working as a senior SCCM and Intune advisor as well as a specialist Microsoft Cloud solutions specialist. Our software and services protect against more risks at more points, more completely and efficiently, enabling confidence wherever information is used or stored. This is useful if you want to populate a native Azure VM that was not installed with SCCM. A successful installation should return an exit code of 0, but that is not always the case. Install Configuration Manager client to the system. When we look at the SMS/SCCM console collection, there is an entry for the client status that indicates either Yes or No. All the different functions I wrote, that were not yet existing in the version 1. We would like the Task Sequence that is advertised to the Unknown Computers Collection to ask for the name of the computer running the task sequence. using SCCM package.